    The effect of unit size on steam-electric generating station design

  • Author

    Mcclure, J. B. ; Mellor, A. G.

  • Author_Institution
    General Electric Company, Schenectady, N. Y.
  • Volume
    71
  • Issue
    2
  • fYear
    1952
  • Firstpage
    174
  • Lastpage
    179
  • Abstract
    As the size of power systems and the capacity of interconnections continue to increase, the economic factors which affect the design of larger generating equipment and stations become more important. Such advantages as lower investment cost per kilowatt, higher efficiency, and lower operating costs are considered in this article.
  • Keywords
    Boilers; Generators; Market research; Oil insulation; Power transformers; Turbines;