DocumentCode
1457745
Title
The role of fuses in appliance protection
Author
Lebens, J. C.
Author_Institution
Bussmann Manufacturing Company, St. Louis, Mo.
Volume
72
Issue
10
fYear
1953
Firstpage
901
Lastpage
903
Abstract
More complicated appliances, performing more functions automatically, connected to larger capacity circuits capable of delivering destructive power under fault conditions, increase markedly the need for electrical protection. Dual-element fuses are recommended to provide complete protection to motor-driven appliances. Appliances with little thermal capacity should be provided with extremely fast-blowing fuses where everything is done to decrease the time delay instead of attempting to build it into the fuse. However the manufacturers´ time-current characteristics facilitate the selection of the proper fuse for a given appliance.
Keywords
Delay effects; Fuses; Heating; Home appliances; Laboratories; Plugs; Strips;
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1953.6438279
Filename
6438279
Link To Document