• DocumentCode
    1458794
  • Title

    The automatic indication and recording of minute concentrations of organic gases in air

  • Author

    Thomas, H.A.

  • Volume
    14
  • Issue
    11
  • fYear
    1954
  • fDate
    11/1/1954 12:00:00 AM
  • Firstpage
    527
  • Lastpage
    543
  • Abstract
    The presence of methanol in an industrial plant is detected by catalytic conversion to CO2 and estimation by infra-red gas analysis. The equipment continuously and sequentially samples the atmosphere from ten points in the plant and gives automatic warning when the methanol concentrations at these points exceed 200 and 1,000 parts in 106. A continuous record is also provided.
  • fLanguage
    English
  • Journal_Title
    Radio Engineers, Journal of the British Institution of
  • Publisher
    iet
  • Type

    jour

  • DOI
    10.1049/jbire.1954.0068
  • Filename
    5258851