DocumentCode :
1459
Title :
Selected diagnostic methods of electrical machines operating in industrial conditions
Author :
Baranski, Marcin ; Decner, Adam ; Polak, Artur
Author_Institution :
Inst. of Electr. Drives & Machines KOMEL, Katowice, Poland
Volume :
21
Issue :
5
fYear :
2014
fDate :
Oct. 2014
Firstpage :
2047
Lastpage :
2054
Abstract :
The article proposes a series of tests on the groundwall insulation, utilizing the dc voltage and consisting of three related procedures. After running the tests, the obtained data are analyzed and insulation is graded in accordance with proposed criteria. These criteria are presented in the paper. The method has been illustrated by real-life example of electrical machine tests´ results. The article describes the turn-to-turn insulation substitute circuit and results of simulations and measurements. There is shown a new diagnostic method to determinate condition of this insulation. The suggested method can be used in any kind of machine and it is easy to use. The most commonly damaged machine parts, except the insulation, are bearings, so the authors decided to mention in the article, about vibration measurements.
Keywords :
condition monitoring; electric machines; insulation testing; machine insulation; production equipment; vibration measurement; DC voltage; damaged machine part; electrical machine test; groundwall insulation; industrial conditions; insulation condition; selected diagnostic method; vibration measurement; Coils; Electrical resistance measurement; Insulation; Resistance; Vibrations; Voltage measurement; Windings; Rotating machine insulation testing; vibration measurement;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/TDEI.2014.004602
Filename :
6927332
Link To Document :
بازگشت