Abstract :
The connection between illuminance and luminance measurements is considered to create a traceability link among a highly accurate illuminance meter, which is considered as an internal standard of the Photometric Laboratory, University of Padova, Padova, Italy, and other illuminance meters or photometric heads and luminance meters. After an introduction on the main involved definitions and equations linking the illuminance and the luminance measurements, this paper presents the instruments to which the procedures are applied and, at the end, results regarding the absolute calibration of the instruments under test, the check of their linearity, and the analysis of their spectral responsivity within the visible range. Following this way, this paper shows the main results in the connection among instruments devoted specifically to illuminance and luminance measurements. Then, it also introduces a comparison to other photometric heads, e.g., sensors that are part of more complex systems, like an integrating sphere for luminous flux measurement. In this last case, it has no significance to evaluate the difference between the absolute outputs, but it is interesting to compare the response of the two devices considering their linearity and their relative spectral response. A special section devoted to the evaluation of the spectral response presents a new simple but effective method. The application of a detector-based method allows a significant reduction of the uncertainty in the internal calibration of the photometric instruments, granting the continuity of the Photometric Laboratory operation contemporarily.
Keywords :
brightness; calibration; lighting; photometers; photometric light sources; photometry; University of Padova; detector-based calibration; illuminance measurements; illuminance meters; luminance measurements; luminance meters; photometric heads; photometric instruments; photometric laboratory operation; spectral responsivity; Illuminance; light-emitting diodes (LEDs); luminance; photometry; spectral analysis; traceability;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2010.2045036
Filename :
5440926
Link To Document :
بازگشت