Title :
The Effect of Photon Statistics and Pulse Shaping on the Performance of the Wiener Filter Crystal Identification Algorithm Applied to LabPET Phoswich Detectors
Author :
Yousefzadeh, Hoorvash Camilia ; Lecomte, Roger ; Fontaine, Réjean
Author_Institution :
Dept. of Electr. & Comput. Eng., Univ. de Sherbrooke, Sherbrooke, QC, Canada
fDate :
6/1/2012 12:00:00 AM
Abstract :
A fast Wiener filter-based crystal identification (WFCI) algorithm was recently developed to discriminate crystals with close scintillation decay times in phoswich detectors. Despite the promising performance of WFCI, the influence of various physical factors and electrical noise sources of the data acquisition chain (DAQ) on the crystal identification process was not fully investigated. This paper examines the effect of different noise sources, such as photon statistics, avalanche photodiode (APD) excess multiplication noise, and front-end electronic noise, as well as the influence of different shaping filters on the performance of the WFCI algorithm. To this end, a PET-like signal simulator based on a model of the LabPET DAQ, a small animal APD-based digital PET scanner, was developed. Simulated signals were generated under various noise conditions with CR-RC shapers of order 1, 3, and 5 having different time constants (τ). Applying the WFCI algorithm to these simulated signals showed that the non-stationary Poisson photon statistics is the main contributor to the identification error of WFCI algorithm. A shaping filter of order 1 with τ = 50 ns yielded the best WFCI performance (error ~1%), while a longer shaping time of τ = 100 ns slightly degraded the WFCI performance (error ~3%). Filters of higher orders with fast shaping time constants (10-33 ns) also produced good WFCI results (error 1.4% to 1.6%). This study shows the advantage of the pulse simulator in evaluating various DAQ conditions and confirms the influence of the detection chain on the WFCI performance.
Keywords :
Poisson distribution; Wiener filters; avalanche photodiodes; data acquisition; nuclear electronics; positron emission tomography; solid scintillation detectors; CR-RC shapers; DAQ conditions; LabPET DAQ; LabPET phoswich detectors; PET-like signal simulator; Wiener filter crystal identification algorithm; avalanche photodiode; crystal identification process; data acquisition chain; electrical noise sources; fast shaping time constants; front-end electronic noise; multiplication noise; noise conditions; nonstationary Poisson photon statistics; photon statistics effect; pulse shaping analysis; pulse simulator; scintillation decay times; shaping filters; small animal APD-based digital PET scanner; Crystals; Data acquisition; Detectors; Noise; Photonics; Positron emission tomography; Signal processing algorithms; Crystal identification; PET-like pulse simulation; Poisson photon statistics; Wiener filter; phoswich detector;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.2012.2186589