DocumentCode :
1462209
Title :
Glass capillary tubes as a high granularity gaseous detector of photons and charged particles
Author :
Peskov, V. ; Silin, E. ; Sokolova, T. ; Radionov, I. ; Gunji, S. ; Sakurai, H.
Author_Institution :
R. Inst. of Technol., Stockholm, Sweden
Volume :
47
Issue :
6
fYear :
2000
fDate :
12/1/2000 12:00:00 AM
Firstpage :
1825
Lastpage :
1828
Abstract :
We demonstrate that glass capillary tubes (GCP´s) can be combined with high efficiency SbCs and bialkali photocathodes. We also report first results from tests of GCP´s combined with solid converters of X-ray photons and with secondary electron emitters
Keywords :
X-ray detection; ionisation chambers; photocathodes; secondary electron emission; solid scintillation detectors; SbCs; X-ray photons; bialkali photocathodes; charged particles; glass capillary tubes; high efficiency; high granularity gaseous detector; secondary electron emitters; solid converters; Cathodes; Detectors; Electron guns; Feedback; Glass; Ionization; Manufacturing; Solids; Testing; Wire;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.914453
Filename :
914453
Link To Document :
بازگشت