    The design of the CDF Run 2 calorimetry readout module

  • Author

    Shaw, Theresa ; Nelson, Charles ; Wesson, Thomas

  • Author_Institution
    Fermi Nat. Accel. Lab., Batavia, IL, USA
  • Volume
    47
  • Issue
    6
  • fYear
    2000
  • fDate
    12/1/2000 12:00:00 AM
  • Firstpage
    1834
  • Lastpage
    1838
  • Abstract
    The CDF calorimetry readout module, called the ADMEM, has been designed to contain both the analog circuitry which digitizes the phototube charge pulses, and the digital logic which supports the readout of the results through the CDF Run 2 DAQ system. The ADMEM module is a 9U×400 mm VMEbus module, which is housed in a CDF VMEbus VIPPA crate. The ADMEM must support near deadtimeless operation, with data being digitized and stored for possible readout every 132 ns or 7.6 MHz. This paper will discuss the implementation of the analog and digital portions of the ADMEM module, and how the board was laid out to avoid the coupling of digital noise into the analog circuitry
  • Keywords
    data acquisition; digital readout; high energy physics instrumentation computing; nuclear electronics; particle calorimetry; system buses; 7.6 MHz; ADMEM; CDF Run 2 calorimetry readout module design; CDF VMEbus VIPPA crate; DAQ system; VMEbus module; near deadtimeless operation; phototube charge pulses; Calibration; Calorimetry; Capacitors; Data acquisition; Field programmable gate arrays; Logic design; Photoelectricity; Pipelines; Pulse circuits; Switches;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.914455
  • Filename
    914455