DocumentCode :
1462222
Title :
The design of the CDF Run 2 calorimetry readout module
Author :
Shaw, Theresa ; Nelson, Charles ; Wesson, Thomas
Author_Institution :
Fermi Nat. Accel. Lab., Batavia, IL, USA
Volume :
47
Issue :
6
fYear :
2000
fDate :
12/1/2000 12:00:00 AM
Firstpage :
1834
Lastpage :
1838
Abstract :
The CDF calorimetry readout module, called the ADMEM, has been designed to contain both the analog circuitry which digitizes the phototube charge pulses, and the digital logic which supports the readout of the results through the CDF Run 2 DAQ system. The ADMEM module is a 9U×400 mm VMEbus module, which is housed in a CDF VMEbus VIPPA crate. The ADMEM must support near deadtimeless operation, with data being digitized and stored for possible readout every 132 ns or 7.6 MHz. This paper will discuss the implementation of the analog and digital portions of the ADMEM module, and how the board was laid out to avoid the coupling of digital noise into the analog circuitry
Keywords :
data acquisition; digital readout; high energy physics instrumentation computing; nuclear electronics; particle calorimetry; system buses; 7.6 MHz; ADMEM; CDF Run 2 calorimetry readout module design; CDF VMEbus VIPPA crate; DAQ system; VMEbus module; near deadtimeless operation; phototube charge pulses; Calibration; Calorimetry; Capacitors; Data acquisition; Field programmable gate arrays; Logic design; Photoelectricity; Pipelines; Pulse circuits; Switches;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.914455
Filename :
914455
Link To Document :
بازگشت