• DocumentCode
    1464022
  • Title

    Measurement of complex permeability by discriminator

  • Author

    Anderson, J.C.

  • Volume
    20
  • Issue
    3
  • fYear
    1960
  • fDate
    3/1/1960 12:00:00 AM
  • Firstpage
    219
  • Lastpage
    223
  • Abstract
    A modified Foster-Seeley discriminator can be used to measure the real and imaginary parts of v.h.f. permeability in a ferromagnetic sample. The circuit is described and the theory and design criteria given. The results of measurements on colloidal nickel in liquid suspension are quoted.
  • Keywords
    discriminators; magnetic permeability measurement; magnetism;
  • fLanguage
    English
  • Journal_Title
    Radio Engineers, Journal of the British Institution of
  • Publisher
    iet
  • Type

    jour

  • DOI
    10.1049/jbire.1960.0022
  • Filename
    5259908