Title :
Frequency compensated A-C ammeters and voltmeters
Author :
Whittenton, J. M. ; Wilkinson, C. A
Author_Institution :
General Electric Company, West Lynn, Mass.
Abstract :
The increased use of a-c instruments over a frequency range of 25 to 3,000 cycles for aircraft and industrial applications has imposed new requirements on instrument design. It is recognized that the standard type of a-c ammeters and voltmeters normally calibrated for use at a given frequency are subject to errors in indication when used at other frequencies. This paper describes the manner in which one line of a-c ammeters and voltmeters can be compensated to have minimum errors resulting from changes in frequency over a range of 25 to 3,000 cycles. Errors found in the uncompensated and compensated types of instruments with changes in frequency are shown, and a practical means of determining the amount of compensation and its application to ammeters and voltmeters is presented.
Keywords :
Ammeters; Coils; Resistance; Resistors; Standards; Voltmeters;
Journal_Title :
Electrical Engineering
DOI :