• DocumentCode
    1468108
  • Title

    High-Current Vacuum Arc: The Relationship Between Anode Phenomena and the Average Opening Velocity of Vacuum Interrupters

  • Author

    Kong, Guowei ; Liu, Zhiyuan ; Wang, Dong ; Rong, Mingzhe

  • Author_Institution
    Dept. of Electr. Eng., Xi´´an Jiaotong Univ., Xi´´an, China
  • Volume
    39
  • Issue
    6
  • fYear
    2011
  • fDate
    6/1/2011 12:00:00 AM
  • Firstpage
    1370
  • Lastpage
    1378
  • Abstract
    In order to understand the influence of the average opening velocity on the high-current vacuum arc anode phenomena, high-speed photography was used to observe the anode phenomena of the vacuum arc discharge in vacuum interrupters. The contact diameters used in the vacuum interrupters were 12 and 25 mm, respectively. The contact materials included Cu, CuCr25, and CuCr50. The arc current frequency was 50 Hz, and the arcing time was controlled at about 9 ms. A permanent magnet mechanism with a contact spring was used to adjust the average opening velocity from 1.3 to 1.8 m/s. The experimental results showed that, with the arc current increasing, there was a threshold current I1st (peak value) at which a high-current anode mode first appeared. Moreover, the first high-current anode mode was a footpoint at the velocity of 1.8 m/s, while, at the velocity of 1.3 m/s, it was most probably an anode spot and sometimes it was a footpoint. The result showed that, at the velocity of 1.8 m/s, the threshold current I1st was lower than that at 1.3 m/s. Moreover, the threshold current I1st followed the order of Cu >; CuCr25 >; CuCr50 at both the velocities of 1.3 m/s and 1.8 m/s. Meanwhile, at the higher average opening velocity of 1.8 m/s, the arc energy and arc voltage were higher than or close to those at 1.3 m/s.
  • Keywords
    chromium alloys; copper; copper alloys; electrochemical electrodes; permanent magnets; springs (mechanical); vacuum arcs; vacuum interrupters; Cu; CuCr; anode phenomena; arc current frequency; contact spring; distance 12 mm; distance 25 mm; frequency 50 Hz; high-current anode mode; high-current vacuum arc discharge; high-speed photography; permanent magnet mechanism; threshold current; time 9 ps; vacuum interrupter velocity; velocity 1.3 m/s to 1.8 m/s; Anodes; Copper; Discharges; Interrupters; Materials; Vacuum arcs; Anode phenomena; high current; opening velocity; vacuum arc; vacuum interrupters;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/TPS.2011.2107529
  • Filename
    5727963