DocumentCode :
1470023
Title :
BES III Time-of-Flight Readout System
Author :
Liu, Shubin ; Feng, Changqing ; An, Qi ; Heng, Yuekun ; Sun, Shengsen
Author_Institution :
Dept. of Modern Phys., Univ. of Sci. & Technol. of China, Hefei, China
Volume :
57
Issue :
2
fYear :
2010
fDate :
4/1/2010 12:00:00 AM
Firstpage :
419
Lastpage :
427
Abstract :
A time-of-flight (TOF) readout system has been developed for a Beijing Spectrometer (BES III). This paper will present an overview of the entire TOF readout system design and its performance in the operation. In a BES III TOF detector, a total of 448 photomultiplier tubes (PMTs) have been installed in barrel and end-cap sections. The corresponding 448 channels´ readout electronics aimed precisely to measure the arrival time of PMT signals from the TOF detector is mainly housed in two VME64xP crates, each crate containing 14 FEE modules, 14 FEE_rear modules, one Fast Control module (FastCtrl), one Clock module, and one Power-PC interface module. Due to the structure of the spectrometer, the two VME crates with 448 channels of readout electronics are placed in two locations; each is 18 m away from the TOF detector. In order to increase the capability of noise immunization and achieve better signal-to-noise ratio, each channel has a preamplifier equipped to PMT base. The preamplifier drives the differential signals over 18 m of shielded twisted-pair cables to the VME crates. The readout system achieved a timing resolution of 25 ps after time-walk and INL corrections. The amplitude-dependent time-walk correction is accomplished by measuring corresponding pulse height. Achieved pulse-height resolution is better than 10 mV in a dynamic range 180-5000 mV. The whole TOF readout system was installed in the spectrometer and has been in operation steadily since then, with the performance well meeting the requirements of the physics experiments.
Keywords :
nuclear electronics; particle spectrometers; photomultipliers; readout electronics; solid scintillation detectors; BES III TOF detector; BES III TOF readout system; Beijing Spectrometer; FEE modules; FEE rear modules; PMT signal arrival time; TOF readout system design; TOF readout system performance; VME crates; amplitude dependent time walk correction; clock module; fast control module; noise immunisation; photomultiplier tubes; power-PC interface module; preamplifier; pulse height measurement; readout electronics; shielded twisted pair cables; time of flight readout system; voltage 180 mV to 5000 mV; Clocks; Detectors; Photomultipliers; Preamplifiers; Pulse measurements; Readout electronics; Signal resolution; Signal to noise ratio; Spectroscopy; Time measurement; Charge measurement; particle identification; time measurement; time-of-flight;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2009.2034520
Filename :
5446530
Link To Document :
بازگشت