DocumentCode
1470119
Title
The accuracy of measurements in lumped R-C cable circuits as used in the study of transient heat flow
Volume
63
Issue
6
fYear
1944
fDate
6/1/1944 12:00:00 AM
Firstpage
426
Lastpage
427
Abstract
E. L. Armi (Leeds and Northrup Company, Philadelphia, Pa.): As stated in part IV, section 1 of the paper, it would be desirable to have theoretical curves for comparison with the experimental results obtained. Fortunately, such curves can easily be plotted for the case illustrated in Figures 13 and 14 of the paper. Carslaw1 and Byerly2 give an expression for the temperature in an infinite slab whose faces are held at fixed temperatures and which has a known temperature distribution at the time t = 0. If appropriate boundary values are used, the expression will read, in symbols of the paper under discussion:
Keywords
Equations; Foot; Heating; IEEE transactions; Mathematical model; Thermal resistance;