Title :
Mass flow measurement with turbine-type flowmeters¿an electronic method of density correction
Author :
Hutcheon, I.C. ; Duffy, L.S.
fDate :
7/1/1963 12:00:00 AM
Abstract :
The temperature of the fuel delivered to an aircraft engine is measured by a silicon resistor, and the volume flow rate is measured by a turbine-type flowmeter fitted with a saturable magnetic pick-off. Electronic circuits convert the transmitted pulse rate and temperature signal into a direct current and into a slightly different pulse rate, both representing the mass rate of flow of fuel. The current operates a rate-meter, and the pulses drive a counter which displays the total mass of fuel consumed. The principles could be applied to industrial mass flow measurement.
Keywords :
aircraft; fuel; instrumentation; magnetic devices; measurement by electrical methods; testing; transistor circuits; velocity measurement;
Journal_Title :
Radio and Electronic Engineer
DOI :