DocumentCode :
14712
Title :
Asymmetric magnetic unit of three-phase IPT system for achieving effective power transmission
Author :
Xia, C.Y. ; Zhang, Juyong ; Jia, N. ; Zhuang, Y.H. ; Wu, X.J.
Author_Institution :
Sch. of Inf. & Electr. Eng., China Univ. of Min. & Technol., Xuzhou, China
Volume :
49
Issue :
11
fYear :
2013
fDate :
May 23 2013
Firstpage :
717
Lastpage :
719
Abstract :
A new asymmetric magnetic unit is proposed, which can effectively eliminate the `dead spot´ in a three-phase IPT (inductive power transfer) system, in which the spiral direction of any one of the three primary coils is opposite to that of the other two, and the pick-up voltage can increase more effectively compared to that of the traditional symmetrical magnetic unit. The viability of the proposed magnetic unit is supported by experiments, the results of which show that the unit plays a key role in the three-phase IPT system design.
Keywords :
inductive power transmission; asymmetric magnetic unit; effective power transmission; inductive power transfer system; pick-up voltage; primary coils; spiral direction; symmetrical magnetic unit; three-phase IPT system design;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el.2012.4132
Filename :
6548189
Link To Document :
بازگشت