DocumentCode
1472218
Title
Current density distribution measurement of negative point-to-plane corona discharge
Author
Madani, Mohammad R. ; Miller, Toby A.
Author_Institution
Dept. of Electr. & Comput. Eng., Southwestern Louisiana Univ., Lafayette, LA, USA
Volume
47
Issue
4
fYear
1998
fDate
8/1/1998 12:00:00 AM
Firstpage
907
Lastpage
913
Abstract
The current density distribution on the plate electrode of a point-to-plane corona discharge is measured with a computer-controlled measuring system. The measurements are taken by rotating the plate which consist of built-in arrays of orthogonal probes. The current-density distribution can be measured for different separation distances between the point electrode and the plane electrode while the applied high voltage can be varied from the voltage required for the onset of corona discharge to 30 kV. The current-density distribution of a single needle is symmetric around its center point within the accuracy of the measurement system. However, the current-density distribution is radially nonuniform. The computer-controlled measuring system is capable of measuring the current distribution of single point and multipoint electrodes
Keywords
CAMAC; computerised instrumentation; corona; current density; current distribution; electric current measurement; electrodes; 30 kV; CAMAC; applied high voltage; built-in arrays; computer-controlled measuring system; current density distribution measurement; multipoint electrodes; negative point-to-plane corona discharge; orthogonal probes; plate electrode; separation distances; single point electrodes; Corona; Current density; Current measurement; Density measurement; Distributed computing; Electrodes; Needles; Probes; Rotation measurement; Voltage;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/19.744641
Filename
744641
Link To Document