Abstract :
Otto A. Knopp (Pacific Gas and Electric Company, San Francisco, Calif.): The authors of this paper have shown that they possess a clear understanding of the physical phenomena involved in the operation of a bushing-type current transformer, and they have developed quite an ingenious method for determining in the field the ratio and phase-angle errors of such transformers.