DocumentCode
1473514
Title
Application of identification methods for predicting the flashover voltage of contaminated insulators covered with ice
Author
Sabri, Y. ; Farzaneh, M. ; Zhang, J.
Author_Institution
Canada Res. on Atmos. Icing Eng. of Power Network (INGIVRE), Univ. du Quebec a Chicoutimi, Chicoutimi, QC, Canada
Volume
17
Issue
2
fYear
2010
fDate
4/1/2010 12:00:00 AM
Firstpage
451
Lastpage
457
Abstract
The arc characteristics on contaminated insulator surfaces covered with ice were investigated. The arc constants (A, n), as well as the ac re-ignition parameters (K, b) were determined using a simplified cylindrical physical model. Based on identification methods, a new approach for calculating the residual voltage is introduced. These results will serve to extend the previous mathematical model developed at CIGELE for its application to predicting the flashover voltage of contaminated insulators covered with ice. The model was successfully applied to a five-unit IEEE standard insulator string, and the calculated results were in good agreement with the experiments.
Keywords
flashover; insulator contamination; CIGELE; IEEE standard insulator string; ac re-ignition parameters; contaminated insulator surfaces; flashover voltage; identification methods; simplified cylindrical physical model; Dielectrics and electrical insulation; Environmentally friendly manufacturing techniques; Flashover; Ice surface; Mathematical model; Pollution; Power system modeling; Road transportation; Surface contamination; Voltage; Outdoor insulation, flashover phenomenon, electrical arc, identification methods, contaminated insulators covered with ice, flashover modeling.;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/TDEI.2010.5448100
Filename
5448100
Link To Document