DocumentCode
1473920
Title
Sampling system for accurate peak voltage measurements
Author
Fiorentin, P.
Author_Institution
Dept. of Electr. Eng., Padova Univ., Italy
Volume
47
Issue
5
fYear
1998
fDate
10/1/1998 12:00:00 AM
Firstpage
1307
Lastpage
1310
Abstract
The paper presents a new method for measuring the peak voltage characterized by a high accuracy. It is based on an integrating analog-to-digital converter. After a brief description of the causes of uncertainty of the method, the criteria of their evaluation are shown. The main characteristics of the used sampling and acquisition system are reported. The method is applied to alternating voltage in the case of distorted waveform also, showing that it can be considered a reference in peak voltage measuring. The results are compared with those obtained by a measuring system based on a different principle: a good agreement between the two methods was found
Keywords
analogue-digital conversion; measurement standards; measurement uncertainty; signal sampling; voltage measurement; voltmeters; waveform analysis; accurate peak voltage measurements; alternating voltage; distorted waveform; integrating analog-to-digital converter; noise effect; reference; sampling system; uncertainty causes; Analog-digital conversion; Dielectric measurements; Distortion measurement; Measurement standards; Sampling methods; Shape measurement; Testing; Uncertainty; Voltage measurement; Voltmeters;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/19.746601
Filename
746601
Link To Document