Title :
Thermoelectric Powered Wireless Sensors for Spent Fuel Monitoring
Author :
Carstens, Thomas A. ; Corradini, Michael L. ; Blanchard, James P. ; Ma, Zhenqiang
Author_Institution :
Department of Engineering Physics, University of Wisconsin-Madison, Madison, WI, USA
Volume :
59
Issue :
4
fYear :
2012
Firstpage :
1408
Lastpage :
1413
Abstract :
This paper describes using thermoelectric generators to power wireless sensors to monitor spent nuclear fuel during dry-cask storage. OrigenArp was used to determine the decay heat of the spent fuel at different times during the service life of the dry-cask. The Engineering Equation Solver computer program modeled the temperatures inside the spent fuel storage facility during its service life. The temperature distribution in a thermoelectric generator and heat sink was calculated using the computer program Finite Element Heat Transfer. From these temperature distributions the power produced by the thermoelectric generator was determined as a function of the service life of the dry-cask. In addition, an estimation of the path loss experienced by the wireless signal can be made based on materials and thickness of the structure. Once the path loss is known, the transmission power and thermoelectric generator power requirements can be determined. This analysis estimates that a thermoelectric generator can produce enough power for a sensor to function and transmit data from inside the dry-cask throughout its service life.
Keywords :
Fuels; Generators; Heat sinks; Heat transfer; Heating; Temperature sensors; Dry cask; spent fuel; thermoelectric generator; wireless transmission;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2012.2187680
Filename :
6172541
Link To Document :
بازگشت