DocumentCode :
1475721
Title :
A simple method for the measurement of varactorq-factor
Author :
Smith, R.B.
Volume :
35
Issue :
4
fYear :
1968
fDate :
4/1/1968 12:00:00 AM
Firstpage :
245
Lastpage :
248
Abstract :
In the proposed method, which is applicable to silicon varactors, measurement is made at a single frequency and the varactor is not matched to the measuring waveguide. The varactor Q-factor is determined from the change in phase of the reflection coefficient between two bias conditions and the voltage standing-wave ratio at one of these. The technique is suitable for production testing.