• DocumentCode
    1476475
  • Title

    Response time and lag of a thermometer element mounted in a protecting case

  • Author

    Goodwin, W. N.

  • Author_Institution
    Weston Electrical Instrument Corporation, Newark, N. J.
  • Volume
    64
  • Issue
    9
  • fYear
    1945
  • Firstpage
    665
  • Lastpage
    670
  • Abstract
    In this paper equations are derived and applied for determining the response time and temperature lag, in general, of a body which exchanges heat with a medium indirectly through a second body. Application is made to a thermometer element mounted in a protecting case, with specific reference to a resistance-type thermometer such as is used for aircraft and marine purposes. The temperature distribution along the stem and the errors resulting when the head of the bulb and medium differ in temperature also are derived.
  • Keywords
    Conductors; Cooling; Electron tubes; Equations; Heating; Temperature distribution; Temperature measurement;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1945.6441264
  • Filename
    6441264