• DocumentCode
    1479431
  • Title

    Dynamic performances of an isolated self-excited induction generator under various loading conditions

  • Author

    Wang, Li ; Su, Jian-Yi

  • Author_Institution
    Dept. of Electr. Eng., Nat. Cheng Kung Univ., Tainan, Taiwan
  • Volume
    14
  • Issue
    1
  • fYear
    1999
  • fDate
    3/1/1999 12:00:00 AM
  • Firstpage
    93
  • Lastpage
    100
  • Abstract
    This paper presents dynamic performances of an isolated self-excited induction generator (SEIG) under different power-factor loading conditions. Both simulated results based on computer simulations and experimental tests based on a laboratory 1.1 kW induction motor driven by a DC motor are clearly compared. Characteristics of both terminal voltage and magnetizing reactance of the studied SEIG subject to sudden connection and disconnection of various power-factor loads are investigated
  • Keywords
    DC motors; asynchronous generators; electric reactance; induction motors; machine theory; magnetisation; power factor; 1.1 kW; DC motor; computer simulations; dynamic performances; induction motor; isolated self-excited induction generator; loading conditions; magnetizing reactance; power-factor loading conditions; power-factor loads; terminal voltage; Computational modeling; Computer simulation; Induction generators; Performance analysis; Power system dynamics; Power system transients; Rotors; Stators; Transient analysis; Voltage;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/60.749153
  • Filename
    749153