Title :
Improved symmetrical component-based fault distance estimation for digital distance protection
Author :
Liao, Y. ; Elangovan, S.
Author_Institution :
Dept. of Electr. Eng., Nat. Univ. of Singapore, Singapore
fDate :
11/1/1998 12:00:00 AM
Abstract :
An improved symmetrical component-based method is proposed in the paper. The proposed method uses phasor estimates of voltage and current samples obtained from both ends of a power transmission line. The mathematical basis of the new approach is described. It is shown that the new method completely obviates complex arithmetic operations and has considerable computational advantages over the previously proposed methods. Furthermore, performance assessment studies on this new method using the alternative transient program (ATP) are presented and discussed. It is illustrated that the proposed method can determine the fault location very accurately and is likely to be used for digital distance protection and fault location
Keywords :
fault location; power transmission lines; power transmission protection; ATP; computational advantages; computer simulation; digital distance protection; fault distance estimation; fault location determination; performance assessment studies; power systems; power transmission line; symmetrical component approach;
Journal_Title :
Generation, Transmission and Distribution, IEE Proceedings-
DOI :
10.1049/ip-gtd:19982366