• DocumentCode
    1482699
  • Title

    In-service winding-temperature measurement

  • Author

    Pavlides, P. K.

  • Author_Institution
    Philadelphia Electric Company, Philadelphia, Pa.
  • Volume
    75
  • Issue
    12
  • fYear
    1956
  • Firstpage
    1091
  • Lastpage
    1091
  • Abstract
    DURING 1954, a radiation pyrometer was developed by the Franklin Institute in conjunction with the Philadelphia Electric Company. It was constructed for the purpose of measuring in-service temperatures on the amortisseur windings of the 25-cycle single-phase generators of two large frequency changers. The temperature measurements which were made with this instrument were the latest in a long series of investigations in connection with recurrent amortisseur winding failures apparently caused by a combination of temperature, stress, and time.
  • Keywords
    Companies; Detectors; Frequency measurement; Generators; Optical recording; Temperature measurement; Windings;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1956.6442315
  • Filename
    6442315