Title :
Measurement of losses and saturated permeability of saturable cores under submicrosecond saturation
Author :
Seki, H. ; Takemori, S. ; Sato, T.
Author_Institution :
Res. Lab., Hitachi Ltd., Ibaraki, Japan
fDate :
11/1/1996 12:00:00 AM
Abstract :
Two specific methods are introduced for obtaining accurate losses and saturated permeability of saturable cores under submicrosecond saturation. One employs an additional inductor for accurate measurement of the losses. The other minimizes stray inductance for accurate measurement of the saturated permeability. The measured relative permeability of Co-based amorphous cores rapidly drops to nearly 1.0. On the other hand, ferrite cores need a much larger magnetic field than that for Co-based amorphous cores in order to obtain the relative permeability of 1.0
Keywords :
amorphous magnetic materials; ferrite devices; inductors; magnetic cores; magnetic leakage; magnetic permeability measurement; pulsed power technology; saturable core reactors; amorphous cores; ferrite cores; inductor; magnetic field; pulsed power supply; relative permeability; saturable cores; saturated permeability; stray inductance; submicrosecond saturation; Inductance; Inductors; Loss measurement; Magnetic cores; Magnetic field measurement; Magnetic flux; Magnetic materials; Permeability measurement; Photonic crystals; Pulsed power supplies;
Journal_Title :
Magnetics, IEEE Transactions on