DocumentCode :
1485340
Title :
A Five-Decade Dynamic-Range Ambient-Light-Independent Calibrated Signed-Spatial-Contrast AER Retina With 0.1-ms Latency and Optional Time-to-First-Spike Mode
Author :
Leñero-Bardallo, Juan Antonio ; Serrano-Gotarredona, Teresa ; Linares-Barranco, Bernabé
Author_Institution :
Centro Nac. de Microelectron., Consejo Super. de Investig. Cientificas, Sevilla, Spain
Volume :
57
Issue :
10
fYear :
2010
Firstpage :
2632
Lastpage :
2643
Abstract :
Address Event Representation (AER) is an emergent technology for assembling modular multiblock bio-inspired sensory and processing systems. Visual sensors (retinae) are among the first AER modules to be reported since the introduction of the technology. Spatial-contrast AER retinae are of special interest since they provide highly compressed data flow without reducing the relevant information required for performing recognition. The reported AER contrast retinae perform a contrast computation based on the ratio between a pixel´s local light intensity and a spatially weighted average of its neighborhood. This resulted in compact circuits but with the penalty of all pixels generating output signals even if they sensed no contrast. In this paper, we present a spatial-contrast retina with a signed output: Contrast is computed as the relative difference (not the ratio) between a pixel´s local light and its surrounding spatial average and normalized with respect to ambient light. As a result, contrast is ambient light independent, includes a sign, and the output will be zero if there is no contrast. Furthermore, an adjustable thresholding mechanism has been included, such that pixels remain silent until they sense an absolute contrast above the adjustable threshold. The pixel contrast-computation circuit is based on Boahen´s biharmonic operator contrast circuit, which has been improved to include mismatch calibration and adaptive-current-based biasing. As a result, the contrast-computation circuit shows much less mismatch, is almost insensitive to ambient light illumination, and biasing is much less critical than in the original voltage biasing scheme. The retina includes an optional global reset mechanism for operation in ambient-light-independent Time-to-First-Spike contrast-computation mode. A 32 32 pixel test prototype has been fabricated in 0.35-m CMOS. Experimental results are provided.
Keywords :
calibration; image recognition; image representation; image sensors; AER; Boahen biharmonic operator; adaptive-current based biasing; address event representation; adjustable thresholding mechanism; ambient light illumination; image recognition; mismatch calibration; pixel local light; spatial-contrast retina; time 0.1 ms; time-to-first-spike mode; visual sensors; Assembly systems; Biosensors; Calibration; Circuits; Delay; Lighting; Retina; Signal generators; Testing; Voltage; Address-event-representation; analog circuits; artificial retina; bio-inspired circuits; calibration; contrast sensors; image sensors; low power circuits; spiking circuits; transistor mismatch;
fLanguage :
English
Journal_Title :
Circuits and Systems I: Regular Papers, IEEE Transactions on
Publisher :
ieee
ISSN :
1549-8328
Type :
jour
DOI :
10.1109/TCSI.2010.2046971
Filename :
5460900
Link To Document :
بازگشت