DocumentCode :
1485616
Title :
Internal corona spaces in cables
Author :
Kitchin, D. W. ; Pratt, O. S.
Author_Institution :
Simplex Wire & Cable Company, Cambridge, Mass.
Volume :
76
Issue :
11
fYear :
1957
Firstpage :
989
Lastpage :
989
Abstract :
IN THE DEVELOPMENT of high-voltage cables insulated with thermoplastics or rubber, it is necessary to measure the corona onset voltage. The manometric method detects internal corona by the decrease in air pressure caused by absorption of corona-activated oxygen. The rate of pressure drop increases rapidly with voltage. By connecting a capillary oil manometer to the sample, this pressure drop can be measured. In this study, all voltages are 60 cycles rms.
Keywords :
Absorption; Cable shielding; Conductors; Corona; Dielectrics; Polyethylene; Silver;
fLanguage :
English
Journal_Title :
Electrical Engineering
Publisher :
ieee
ISSN :
0095-9197
Type :
jour
DOI :
10.1109/EE.1957.6442814
Filename :
6442814
Link To Document :
بازگشت