    Development of a High Resolution X-Ray CT Technique for Irradiated Fuel Pellets

  • Author

    Katsuyama, Kozo ; Ishimi, Akihiro ; Maeda, Koji ; Nagamine, Tsuyoshi ; Asaga, Takeo

  • Author_Institution
    Oarai Research and Development Center, Japan Atomic Energy Agency, Ibaraki, Japan
  • Volume
    59
  • Issue
    4
  • fYear
    2012
  • Firstpage
    1397
  • Lastpage
    1400
  • Abstract
    A nondestructive method making use of X-ray computer tomography (X-ray CT) has been applied to post irradiation examinations (PIEs) of fast breeder reactor (FBR) fuel assemblies. In the X-ray CT system, a 12 MeV X-ray pulse was used in synchronization with switching on the detector to minimize the effects of gamma ray emissions from the irradiated fuel assemblies. This technique enables a clear cross section CT images of the irradiated fuel assembly to be obtained.
  • Keywords
    Assembly; Computed tomography; Detectors; Fuels; Image resolution; Pins; X-ray imaging; Fast breeder reactor; X-ray computer tomography; fuel pellets;