Abstract :
The various parameters influencing the eddy-current losses and unbalance in electrode arms of an arc furnace are investigated. The volume integral equation method is used. Current distribution, phase impedance, bus-voltage drop, and power loss are presented for various bus positions and arm configurations. Experiments conducted in the laboratory have confirmed the calculations
Keywords :
arc furnaces; current distribution; eddy current losses; integral equations; arc furnace; arm configurations; bus positions; bus-voltage drop; current distribution; eddy-current losses; electrode arms unbalance; phase impedance; power loss; volume integral equation method; Arm; Circuits; Conductors; Current density; Current distribution; Eddy currents; Electrodes; Equations; Proximity effect; Voltage;