DocumentCode :
1486959
Title :
Eddy current losses and unbalance in electrode arms
Author :
Cao, M. ; Biringer, P.P. ; Bulat, V.
Author_Institution :
Dept. of Electr. Eng., Toronto Univ., Ont., Canada
Volume :
24
Issue :
6
fYear :
1988
fDate :
11/1/1988 12:00:00 AM
Firstpage :
2670
Lastpage :
2672
Abstract :
The various parameters influencing the eddy-current losses and unbalance in electrode arms of an arc furnace are investigated. The volume integral equation method is used. Current distribution, phase impedance, bus-voltage drop, and power loss are presented for various bus positions and arm configurations. Experiments conducted in the laboratory have confirmed the calculations
Keywords :
arc furnaces; current distribution; eddy current losses; integral equations; arc furnace; arm configurations; bus positions; bus-voltage drop; current distribution; eddy-current losses; electrode arms unbalance; phase impedance; power loss; volume integral equation method; Arm; Circuits; Conductors; Current density; Current distribution; Eddy currents; Electrodes; Equations; Proximity effect; Voltage;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.92208
Filename :
92208
Link To Document :
بازگشت