• DocumentCode
    1487380
  • Title

    High-Resolution Versus High-Sensitivity SPECT Imaging With Geometric Blurring Compensation for Various Parallel-Hole Collimation Geometries

  • Author

    Zhang, Bin ; Zeng, Gengsheng L.

  • Author_Institution
    Univ. of Utah, Salt Lake City, UT, USA
  • Volume
    14
  • Issue
    4
  • fYear
    2010
  • fDate
    7/1/2010 12:00:00 AM
  • Firstpage
    1121
  • Lastpage
    1127
  • Abstract
    Recent studies have shown that trading efficiency for improved resolution may be a good choice for small lesion detection, but utilizing collimator with high efficiency may be more favorable for cardiac single photon emission computed tomography (SPECT). This paper investigates the tradeoffs of geometric-blurring compensation for high-resolution (HR) and high-sensitivity (HS) SPECT imaging with various parallel-hole collimators in terms of noise reduction and resolution recovery. Five types of collimators were investigated and compared with a general all purpose collimator using computer simulations. It is shown that less noisy SPECT images can be achieved with unchanged spatial resolution using large collimator holes with blurring compensation. The optimal collimator hole found in the computer simulation is the one with a hole acceptance angle in the range from 6.3° to 9.4°. Phantom experiments with two cardiac-insert phantoms show that the resolution of the image obtained using the HS collimator can be successfully recovered by blurring compensation, and the image is less noisy compared to the one obtained using the HR collimator.
  • Keywords
    cardiology; collimators; image denoising; image enhancement; image resolution; medical image processing; phantoms; single photon emission computed tomography; HS collimator; cardiac single photon emission computed tomography; cardiac-insert phantoms; geometric blurring compensation; high-resolution versus high-sensitivity SPECT imaging; noise reduction; resolution recovery; small lesion detection; various parallel-hole collimation geometry; Collimator; high-sensitivity (HS); resolution compensation; single photon emission computed tomography (SPECT); Models, Anatomic; Models, Theoretical; Sensitivity and Specificity; Tomography, Emission-Computed, Single-Photon;
  • fLanguage
    English
  • Journal_Title
    Information Technology in Biomedicine, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1089-7771
  • Type

    jour

  • DOI
    10.1109/TITB.2010.2050145
  • Filename
    5462857