DocumentCode :
1487908
Title :
Advances in the development of encapsulant for mercuric iodide x-ray detectors
Author :
Iwanczyk, J.S. ; Wang, Y.J. ; Bradley, J.G. ; Albee, A.L. ; Schnepple, W.F.
Author_Institution :
Xsirius, Inc. (formerly the Institute of Physics, University of Southern California), 4640 Admiralty Way, Suite 214, Marina del Ray, CA 90292.
Volume :
37
Issue :
6
fYear :
1990
fDate :
12/1/1990 12:00:00 AM
Firstpage :
2214
Lastpage :
2218
Abstract :
Advances in the development of protective impermeable encapsulants with high transparency to ultra-low-energy X-rays for use on HgI, X-ray detectors are reported. Various X-ray fluorescence spectra from coated detectors are presented. The X-ray absorption in the encapsulants has been analyzed using characteristic radiation from various elements. Results suggest that low-energy cutoffs for the detectors are not determined solely by the encapsulating coatings presently employed but are also influenced by the front electrode and surface effects, which can affect the local electric field or the surface recombination velocity. An energy resolution of 182 eV (FWHM) has been achieved for Ni L lines at 850 eV. Improved detector sensitivity to X-ray energies under 700 eV is demonstrated.
Keywords :
Attenuation; Coatings; Electrodes; Electromagnetic wave absorption; Encapsulation; Fluorescence; Marine technology; Protection; X-ray detection; X-ray detectors;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1990.574217