DocumentCode :
1487911
Title :
Interpolation methods for time-delay estimation using cross-correlation method for blood velocity measurement
Author :
Lai, Xiaoming ; Torp, Hans
Author_Institution :
Dept. of Med. Biophys., Toronto Univ., Ont., Canada
Volume :
46
Issue :
2
fYear :
1999
fDate :
3/1/1999 12:00:00 AM
Firstpage :
277
Lastpage :
290
Abstract :
The cross-correlation method (CCM) for blood flow velocity measurement using Doppler ultrasound is based on time delay estimation of echoes from pulse-to-pulse. The sampling frequency of the received signal is usually kept as low as possible in order to reduce computational complexity, and the peak in the correlation function is found by interpolating the correlation function. The parabolic-fit interpolation method introduces a bias at low sampling rate to the ultrasound center frequency ratio. In this study, four different methods are suggested to improve the estimation accuracy: (1) Parabolic interpolation with bias-compensation, derived from a theoretical signal model. (2) Parabolic interpolation combined with linear filter interpolation of the correlation function. (3) Parabolic interpolation to the complex correlation function envelope. (4) Matched filter interpolation applied to the correlation function. The new interpolation methods are analyzed both by computer simulated signals and RF-signals recorded from a patient with time delay larger than 1/f/sub 0/, where f/sub 0/ is the center frequency. The simulation results show that these methods are more accurate than the parabolic-fit method. From the simulation, the worst estimation accuracy is about 1.25% of 1/f/sub 0/ for the parabolic-fit interpolation, and it is improved by the above methods to less than 0.5% of 1/f/sub 0/ when the sampling rate is 10 MHz, the center frequency is 2.5 MHz and the bandwidth is 1 MHz. This improvement also can be observed in the experimental data. Furthermore, the matched filter interpolation gives the best performance when signal-to-noise ratio (SNR) is low. This is verified both by simulation and experimentation.
Keywords :
Doppler measurement; acoustic correlation; biomedical ultrasonics; blood flow measurement; delay estimation; interpolation; medical signal processing; Doppler ultrasound; RF signal processing; blood velocity measurement; computer simulation; cross-correlation method; matched filter interpolation; noninvasive clinical diagnosis; parabolic interpolation; pulse echo; time delay estimation; Blood flow; Computational modeling; Delay effects; Delay estimation; Frequency estimation; Interpolation; Matched filters; Sampling methods; Ultrasonic imaging; Velocity measurement;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/58.753016
Filename :
753016
Link To Document :