• DocumentCode
    1488498
  • Title

    Starting problems associated with a transformer coupled load in a series inverter

  • Author

    Jain, Praveen ; Dewan, S.B.

  • Author_Institution
    Canadian Astronaut. Ltd., Ottawa, Ont., Canada
  • Volume
    24
  • Issue
    6
  • fYear
    1988
  • fDate
    11/1/1988 12:00:00 AM
  • Firstpage
    2895
  • Lastpage
    2897
  • Abstract
    The voltage source series inverter with a transformer-coupled induction heating load suffers from either latching or commutation failure when starting under certain load conditions. The load conditions that cause starting failure are determined. The commutating and latching current capabilities of the inverter are obtained by a transient analysis of the invertor for the first half cycle. The requirements for successful operation of the inverter are discussed, and the regions for successful and unsuccessful commutation and latching of the inverter are given
  • Keywords
    commutation; induction heating; invertors; starting; commutation failure; first half cycle; latching current capabilities; latching failure; load conditions; requirements for successful operation; series inverter; starting failure; starting problems; transformer coupled load; transformer-coupled induction heating load; transient analysis; voltage source series inverter; Diodes; Equivalent circuits; Impedance matching; Magnetic analysis; Resistance heating; Resonant inverters; Space heating; Switches; Switching circuits; Transient analysis;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.92280
  • Filename
    92280