Partial response signaling in a magnetic recording channel
Author :
Moon, Jaekyun J. ; Carley, L. Richard
Author_Institution :
Dept. of Electr. & Comput. Eng., Carnegie-Mellon Univ., Pittsburgh, PA, USA
Volume :
24
Issue :
6
fYear :
1988
fDate :
11/1/1988 12:00:00 AM
Firstpage :
2973
Lastpage :
2975
Abstract :
A number of partial-response (PR) systems that are suitable for magnetic recording are discussed. The error probabilities in bit-by-bit detection are obtained as functions of the signal-to-noise ratio (SNR) at the playback point under the assumptions of raised cosine equalization, additive Gaussian noise, and the presence of timing errors. Both low- and high-density performances are considered. The effect of narrowband amplitude-modulation noise is also considered
Keywords :
error statistics; magnetic recording; additive Gaussian noise; bit-by-bit detection; error probabilities; magnetic recording channel; narrowband amplitude-modulation noise; partial-response; playback point; raised cosine equalization; signal-to-noise ratio; timing errors; Additive noise; Equalizers; Error probability; Gaussian noise; Magnetic recording; Multi-stage noise shaping; Partial response signaling; Signal to noise ratio; Timing; Transfer functions;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.92305