DocumentCode :
1494447
Title :
A comparison of the performance of planar and conventional second-order gradiometers coupled to a SQUID for the NDT of steel plates
Author :
Evanson, S. ; Bain, R.J.P. ; Donaldson, G.B. ; Stirling, G. ; Hayward, G.
Author_Institution :
Strathclyde Univ., Glasgow, UK
Volume :
25
Issue :
2
fYear :
1989
fDate :
3/1/1989 12:00:00 AM
Firstpage :
1200
Lastpage :
1203
Abstract :
The authors have developed a DC magnetic NDT (nondestructive testing) technique using a SQUID (superconducting quantum interference device) coupled to a planar gradiometer for the inspection of structures such as flat steel plates and steel pipes. Design criteria for the gradiometer are presented and used to demonstrate the superior performance of the planar approach compared to that of a second-order axial gradiometer of conventional design. The authors show an example of the use of system for mapping the magnetic field above a steel plate containing ideal defects. The proposed SQUID system is shown to operate normally in an unscreened laboratory close to a steel specimen in the presence of a DC magnetizing field in excess of 20 mT
Keywords :
SQUIDs; magnetometers; nondestructive testing; DC magnetizing field; NDT; SQUID; ideal defects; magnetic field; mapping; nondestructive testing; second-order gradiometers; steel pipes; steel plates; Couplings; Inspection; Interference; Magnetic devices; Magnetic fields; Nondestructive testing; SQUIDs; Steel; Superconducting devices; Superconducting magnets;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.92511
Filename :
92511
Link To Document :