Title :
A new method to reduce addressing time in a large AC plasma display panel
Author :
Park, Chung-Hoo ; Kim, Dong-Hyun ; Lee, Sung-Hyun ; Ryu, Jae-Hwa ; Cho, Jung-Soo
Author_Institution :
Dept. of Electr. Eng., Pusan Nat. Univ., South Korea
fDate :
6/1/2001 12:00:00 AM
Abstract :
To replace the dual scan system by single scan in large ac plasma display panel (PDP), the addressing time should be reduced by modifying cell structure and/or driving circuits. Moreover, the luminance of the PDP can also be increased with the decrease in the addressing time. In this paper, we suggest the bus and address electrodes with triangular protruding tips in order to reduce the addressing time. Moreover, the addressing time of the ac PDP with these electrodes was investigated experimentally with address and display period separated (ADS) driving method. The experimental results show that the addressing time can be reduced more than 30% compared with the conventional type by modifying the electrodes without reducing the luminance of the PDP
Keywords :
brightness; driver circuits; electrodes; large screen displays; plasma displays; address and display period separated method; address electrodes; addressing time; cell structure; driving circuits; electrodes; large AC plasma display panel; luminance; single scan system; triangular protruding tips; Capacitance; Circuits; Costs; Crosstalk; Electrodes; HDTV; Plasma displays; Shape; Voltage; Writing;
Journal_Title :
Electron Devices, IEEE Transactions on