    Voltage dip in A-C generators

  • Author

    Rosenberg, L. T.

  • Author_Institution
    Allis-Chalmers Manufacturing Company, Milwaukee, Wis.
  • Volume
    68
  • Issue
    7
  • fYear
    1949
  • fDate
    7/1/1949 12:00:00 AM
  • Firstpage
    589
  • Lastpage
    589
  • Abstract
    THE MAGNITUDE and duration of the voltage dip during sudden application of load to an a-c generator under regulator action often is required to determine disturbance to other equipment on the system. Point-by-point methods, although accurate, require considerable time to apply. An analytical solution has been used covering machines with self-excited exciters operating below appreciable saturation. The first few cycles generally were disregarded as this permits neglecting the effect of dampers and sub transient voltage drop.