• DocumentCode
    1500248
  • Title

    Design Considerations of Soft-Switched Buck PFC Converter With Constant On-Time (COT) Control

  • Author

    Wu, Xinke ; Yang, Jianyou ; Zhang, Junming ; Xu, Ming

  • Author_Institution
    Coll. of Electr. Eng., Zhejiang Univ., Hangzhou, China
  • Volume
    26
  • Issue
    11
  • fYear
    2011
  • Firstpage
    3144
  • Lastpage
    3152
  • Abstract
    In contrast to the conventional boost power factor correction (PFC) converter, the buck PFC converter can achieve high efficiency in the entire universal input voltage range. A critical conduction mode (CRM) soft-switched buck PFC converter with constant on-time control is presented in this paper. The design methodology and criteria for zero-voltage switching range, high efficiency and low harmonics of the CRM buck ac-dc converter are achieved. A 100-W prototype built up according to the proposed design criteria shows that the input current harmonics meet the IEC61000-3-2 (Class D) standard and the efficiency is higher than 0.965 during the universal input range.
  • Keywords
    power factor correction; switching convertors; zero voltage switching; IEC61000-3-2 Class D standard; boost power factor correction converter; constant on-time control; critical conduction mode; current harmonics; power 100 W; soft-switched buck PFC converter; zero-voltage switching; Capacitors; Converters; Harmonic analysis; Inductors; Switches; Zero voltage switching; AC–DC; buck power factor correction (PFC); high efficiency; zero-voltage switching (ZVS);
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/TPEL.2011.2145391
  • Filename