• DocumentCode
    1502208
  • Title

    Minimum variance beamforming applied to ultrasound imaging with a partially shaded aperture

  • Author

    Mehdizadeh, Saeed ; Austeng, Andreas ; Johansen, Tonni F. ; Holm, Sverre

  • Author_Institution
    Dept. of Circulation & Med. Imaging, Norwegian Univ. of Sci. & Technol., Trondheim, Norway
  • Volume
    59
  • Issue
    4
  • fYear
    2012
  • fDate
    4/1/2012 12:00:00 AM
  • Firstpage
    683
  • Lastpage
    693
  • Abstract
    Shadowing of an imaging aperture occurs when ultrasound beams are partially obstructed by an acoustically hard tissue, e.g., bone tissue. This effect leads to reduced resolution and, in some cases, geometrical distortion. In this paper, we initially introduce a binary apodization model to simulate effects of the shadowing on the point scatterers located close to a bone structure. Further, in a simulation study and an in vitro experiment, the minimum variance (MV) beamforming method is employed to image scatterers partly located in the shadow of bone. We show that the MV beamformer can result in a distorted image when the imaging aperture is highly obstructed by the bone structure. This distortion can be seen as an apparent lateral shift of the point spread function and a decrease in the sensitivity. Based on the signal power across the aperture, we adaptively determine the shadowed elements and discard their corresponding data from the covariance matrix to improve the MV beamformer performance. This modified MV beamformer can retain the resolution and compensate for the apparent lateral shifting and signal attenuation for the shadowed point scatterers.
  • Keywords
    array signal processing; biomedical optical imaging; biomedical ultrasonics; bone; image resolution; medical image processing; optical transfer function; sensitivity; ultrasonic imaging; acoustically hard tissue; apparent lateral shifting; binary apodization model; bone structure; bone tissue; covariance matrix; geometrical distortion; image resolution; image scatterers; imaging aperture shadowing; minimum variance beamforming; partially shaded aperture; point scatterers; point spread function; sensitivity; signal attenuation; ultrasound imaging; Apertures; Array signal processing; Bones; Covariance matrix; Imaging; Shadow mapping; Ultrasonic imaging; Algorithms; Computer Simulation; Humans; Image Processing, Computer-Assisted; Models, Theoretical; Needles; Phantoms, Imaging; Signal Processing, Computer-Assisted; Spine; Ultrasonography, Interventional;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2012.2246
  • Filename
    6189175