DocumentCode :
1502615
Title :
Lumped parameter thermal model for electrical machines of TEFC design
Author :
Mellor, P.H. ; Roberts, D. ; Turner, D.R.
Author_Institution :
Dept. of Electr. Eng. & Electron., Liverpool Univ., UK
Volume :
138
Issue :
5
fYear :
1991
fDate :
9/1/1991 12:00:00 AM
Firstpage :
205
Lastpage :
218
Abstract :
The model described provides both a steady-state and transient solution to the temperatures within an electrical machine of the TEFC design. The model is sufficiently complex to identify the temperatures at most locations in the machine, including the peak temperatures in the endwinding and the surface temperatures of the rotor. It is formulated out of purely dimensional information and constant thermal coefficients and is therefore easily adapted to a range of frame sizes. The thermal behaviour of the TEFC machine is accurately described by the solution of just eight linear differential equations. The model is therefore suitable for application to online temperature estimation for protection and duty-cycle evaluation. The application of the thermal model to a medium (75 kW) and two small (5.5 kW) induction motors is described in detail. The model performance is confirmed by experimental temperature data obtained from varying load tests on each of the three induction motors
Keywords :
induction motors; rotors; thermal analysis; transients; 5.5 kW; 75 kW; TEFC design; duty-cycle evaluation; electrical machines; endwinding; lumped parameter thermal model; online temperature estimation; peak temperatures; protection; rotor; steady-state solution; surface temperatures; temperatures; transient solution;
fLanguage :
English
Journal_Title :
Electric Power Applications, IEE Proceedings B