• DocumentCode
    1503138
  • Title

    Calibration of Rogowski Coils With an Integrator at High Currents

  • Author

    Draxler, Karel ; Styblikova, Renata ; Hlavacek, Jan ; Prochazka, Radek

  • Author_Institution
    Dept. of Meas., Czech Tech. Univ. in Prague, Prague, Czech Republic
  • Volume
    60
  • Issue
    7
  • fYear
    2011
  • fDate
    7/1/2011 12:00:00 AM
  • Firstpage
    2434
  • Lastpage
    2438
  • Abstract
    This paper describes the calibration of Rogowski coils with an integrator for current measurement in the current range of up to 30 kA, at mains frequency. A current loop of ten turns with a current of 3 kA was used for calibration. The magnetic field generated in this way differs from the field of one turn placed at the center and passed with a current of 30 kA. The influence of the unevenness of winding and the cross section of the Rogowski coil may cause a calibration error when using a current loop. The difference in the results between using a current loop and one turn, and the measurement uncertainties are given here. Calculations of the mutual inductances of typical Rogowski coils and their uncertainties are presented in the Appendix.
  • Keywords
    calibration; coils; electric current measurement; integrating circuits; measurement uncertainty; Rogowski coils; calibration error; current 3 kA; current 30 kA; current loop; current measurement; integrator; measurement uncertainty; winding unevenness; Calibration; Coils; Conductors; Current measurement; Inductance; Uncertainty; Voltage measurement; Calibration; Rogowski coil (Rc); cross-section winding; high currents; winding unevenness;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2011.2126090
  • Filename
    5755193