DocumentCode
1504675
Title
Time effective methods of calculation of maximum time interval error
Author
Dobrogowski, Andrzej ; Kasznia, Michal
Author_Institution
Inst. of Electron. & Telecommun., Poznan Tech. Univ., Poland
Volume
50
Issue
3
fYear
2001
fDate
6/1/2001 12:00:00 AM
Firstpage
732
Lastpage
741
Abstract
In this paper, the time effective calculation methods of the maximum time interval error estimate (MTˆIE) are proposed. The formula of the MTIE estimator and the time error sequence measurement conditions are presented. The method of MTˆIE calculation based directly on the estimator´s definition is the first method presented. Then the methods which enable computation of the MTIE estimate in a rather short time are proposed. The experiment of MTˆIE calculation using the presented method is described. The comparison between the methods is made. The pros and cons of the proposed methods are pointed out
Keywords
error analysis; measurement errors; synchronisation; time measurement; timing; MTIE estimator; maximum time interval error; telecommunication network; time error sequence measurement; time interval; timing signal; Clocks; Error correction; Frequency synchronization; Instruments; Process control; Root mean square; Standardization; Telecommunication computing; Time measurement; Timing;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/19.930447
Filename
930447