• DocumentCode
    1504951
  • Title

    Matching 3-D Prone and Supine CT Colonography Scans Using Graphs

  • Author

    Wang, Shijun ; Petrick, Nicholas ; Van Uitert, Robert L. ; Periaswamy, Senthil ; Wei, Zhuoshi ; Summers, Ronald M.

  • Author_Institution
    Lab., Radiol. & Imaging Sci, Nat. Inst. of Health Clinical Center, Bethesda, MD, USA
  • Volume
    16
  • Issue
    4
  • fYear
    2012
  • fDate
    7/1/2012 12:00:00 AM
  • Firstpage
    676
  • Lastpage
    682
  • Abstract
    In this paper, we propose a new registration method for prone and supine computed tomographic colonography scans using graph matching. We formulate 3-D colon registration as a graph matching problem and propose a new graph matching algorithm based on mean field theory. In the proposed algorithm, we solve the matching problem in an iterative way. In each step, we use mean field theory to find the matched pair of nodes with highest probability. During iterative optimization, one-to-one matching constraints are added to the system in a step-by-step approach. Prominent matching pairs found in previous iterations are used to guide subsequent mean field calculations. The proposed method was found to have the best performance with smallest standard deviation compared with two other baseline algorithms called the normalized distance along the colon centerline (NDACC) ( p = 0.17) with manual colon centerline correction and spectral matching ( p <; 1e-5). A major advantage of the proposed method is that it is fully automatic and does not require defining a colon centerline for registration. For the latter NDACC method, user interaction is almost always needed for identifying the colon centerlines.
  • Keywords
    computerised tomography; endoscopes; graph theory; image matching; image registration; iterative methods; medical image processing; optimisation; 3D colon registration; 3D prone CT colonography scans; 3D supine CT colonography scans; CT colonography scan matching; NDACC; colon centerline normalized distance; computed tomographic colonography scans; graph matching algorithm; graph matching problem; image registration method; iterative method; iterative optimization; manual colon centerline correction; matched node pair; mean field theory; one to one matching constraints; spectral matching; step by step approach; Colon; Data models; Humans; Manuals; Probabilistic logic; Registers; Three dimensional displays; Computed tomographic colonography; colon registration; graph matching; mean field theory; Aged; Algorithms; Colon; Colonic Polyps; Colonography, Computed Tomographic; Humans; Image Processing, Computer-Assisted; Male;
  • fLanguage
    English
  • Journal_Title
    Information Technology in Biomedicine, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1089-7771
  • Type

    jour

  • DOI
    10.1109/TITB.2012.2194297
  • Filename
    6191352