DocumentCode
1505939
Title
Choosing electric turbocompressor drivers
Author
Kleiner, Fritz ; Ponick, Bernd ; De Wit, Bas
Author_Institution
Siemens AG, Erlangen, Germany
Volume
7
Issue
4
fYear
2001
Firstpage
45
Lastpage
52
Abstract
High-speed electric motor variable speed drives used to drive centrifugal compressors of any size are proven technology, and the examples shown in this paper are exemplary for many other successful inscallations. Economics will not always justify their use, particularly if there is no reliable and economical source of electric power available at site, but most applications can ill-afford not to evaluate them. There are a number of success factors in the proper design and use of very large VSD systems that will make such systems a success: thoroughly match the compressor´s torque-speed envelope with available drive designs; consider all system components combined-their characteristics and capabilities must be carefully matched; close cooperation of the compressor and motor manufacturer is of paramount importance; vibration and harmonic analyses prior to manufacturing are mandatory and may have consequences on the final electrical and mechanical design; and an integrated and coordinated protection and control system increases system transparency and reliability
Keywords
centrifuges; compressors; motor drives; variable speed drives; coordinated protection/control system; electric turbocompressor drivers selection; electrical design; mechanical design; reliability; torque-speed envelope; transparency; variable speed motor drives; Compressors; Electric motors; Harmonic analysis; Manufacturing; Power generation economics; Power system economics; Power system reliability; Protection; Variable speed drives; Vibration control;
fLanguage
English
Journal_Title
Industry Applications Magazine, IEEE
Publisher
ieee
ISSN
1077-2618
Type
jour
DOI
10.1109/2943.930990
Filename
930990