• DocumentCode
    1508525
  • Title

    Evaluation of a rehabilitative pedorthic: plantar pressure alterations with scaphoid pad application

  • Author

    Abu-Faraj, Ziad O. ; Harris, Gerald F. ; Chang, An-Hsiung ; Shereff, Michael J.

  • Volume
    4
  • Issue
    4
  • fYear
    1996
  • fDate
    12/1/1996 12:00:00 AM
  • Firstpage
    328
  • Lastpage
    336
  • Abstract
    Scaphoid or longitudinal arch pads are frequently prescribed pedorthics for foot and ankle rehabilitation. These pedorthics are reported to be effective in mechanically supporting the medial longitudinal arch while reducing plantar and medial soft tissue strain. The objective of this study was to measure alterations in ambulatory planter pressure metrics in a group of adults secondary to scaphoid pad application. The biomechanical rationale of this study was that the geometry of foot contact would be altered secondary to foot inversion. Ten adult male subjects with biomechanically normal feet were evaluated during multiple trials. A Holter type microprocessor-based portable in-shoe plantar pressure data acquisition system was used to record the dynamic data. Pressures were recorded from eight discrete planter locations at the hindfoot, midfoot, and forefoot regions of the insole. Statistically significant (p⩽0.05) increases in peak pressures were seen laterally with scaphoid pad application, while significant decreases in peak pressures with pad usage occurred at the hallux and the calcaneal region of the foot. At the medial longitudinal arch, peak pressures increased from near 0 to 115.3 kPa, contact durations increased from near 0 to 438 ms, and pressure-time integrals increased from near 0 to 33.4 kPa·s
  • Keywords
    biomechanics; orthotics; pressure measurement; 0 to 115.3 kPa; 0 to 438 ms; Holter type microprocessor-based system; adult male subjects; ankle rehabilitation; biomechanical rationale; biomechanically normal feet; foot; foot contact geometry; insole; longitudinal arch pads; mechanical support; medial longitudinal arch; plantar pressure alterations; rehabilitative pedorthic; scaphoid pad application; soft tissue strain reduction; Atherosclerosis; Biological tissues; Biomedical engineering; Capacitive sensors; Foot; Footwear; Orthopedic surgery; Pain; Pressure measurement; Stability;
  • fLanguage
    English
  • Journal_Title
    Rehabilitation Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1063-6528
  • Type

    jour

  • DOI
    10.1109/86.547934
  • Filename
    547934