• DocumentCode
    1508535
  • Title

    Fast spatio-temporal image reconstruction for dynamic PET

  • Author

    Wernick, Miles N. ; Infusino, E. James ; Milosevic, Milica

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Illinois Inst. of Technol., Chicago, IL, USA
  • Volume
    18
  • Issue
    3
  • fYear
    1999
  • fDate
    3/1/1999 12:00:00 AM
  • Firstpage
    185
  • Lastpage
    195
  • Abstract
    In tomographic imaging, dynamic images are typically obtained by reconstructing the frames of a time sequence independently, one by one. A disadvantage of this frame-by-frame reconstruction approach is that it fails to account. For temporal correlations in the signal. Ideally, one should treat the entire image sequence as a single spatio-temporal signal. However, the resulting reconstruction task becomes computationally intensive. Fortunately, as the authors show in this paper, the spatio-temporal reconstruction problem call be greatly simplified by first applying a temporal Karhunen-Loeve (KL) transformation to the imaging equation. The authors show that if the regularization operator is chosen to be separable into space and time components, penalized weighted least squares reconstruction of the entire image sequence is approximately equivalent to frame-by-frame reconstruction in the space-KL domain. By this approach, spatio-temporal reconstruction can be achieved at reasonable computational cost. One can achieve further computational savings by discarding high-order KL components to avoid reconstructing them. Performance of the method is demonstrated through statistical evaluations of the bias-variance tradeoff obtained by computer simulation reconstruction.
  • Keywords
    Karhunen-Loeve transforms; image reconstruction; image sequences; medical image processing; positron emission tomography; principal component analysis; bias-variance tradeoff; computer simulation reconstruction; dynamic PET; fast spatio-temporal image reconstruction; imaging equation; medical diagnostic imaging; nuclear medicine; penalized weighted least squares reconstruction; regularization operator; space components; temporal Karhunen-Loeve transformation; time components; time sequence frames reconstruction; Computational efficiency; Computer simulation; Equations; High-resolution imaging; Image reconstruction; Image resolution; Image sequences; Least squares approximation; Positron emission tomography; Principal component analysis; Computer Simulation; Humans; Image Processing, Computer-Assisted; Models, Statistical; Phantoms, Imaging; Reproducibility of Results; Tomography, Emission-Computed;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/42.764885
  • Filename
    764885