Title :
Average Absolute Frequency Deviation Value Based Active Islanding Detection Technique
Author :
Gupta, Pankaj ; Bhatia, R.S. ; Jain, D.K.
Author_Institution :
Dept. of Electron. & Commun. Eng., Indira Gandhi Delhi Tech. Univ. for Women, New Delhi, India
Volume :
6
Issue :
1
fYear :
2015
fDate :
Jan. 2015
Firstpage :
26
Lastpage :
35
Abstract :
An average absolute frequency deviation value based active islanding detection technique is proposed in this paper. The inverter´s classical q-axis current controller is modeled with a continuous periodic reference current of a small value. During the loss of mains, the island´s frequency deviates with respect to the variation in the reference current; this is detected by making the use of an average absolute frequency deviation value. In case of a stable island formation, there is a small periodic frequency deviation owing to the small value of the periodic reference current, and the frequency deviation is so small that it falls inside the nondetection zone (NDZ) of the frequency relay. The main advantage of the proposed algorithm is that it detects the stable island formation but without forcing the island to lose its stable operation. In case of nonislanding switching events, which may transiently impose a significant deviation in the frequency, the possibility of false detection is eliminated by reconfirming the occurrence of islanding once it is suspected. The reference current is kept to a small value to limit the degradation of the power quality and the power factor. Computer simulation is done with MATLAB.
Keywords :
distributed power generation; electric current control; frequency control; invertors; power factor; power generation control; power supply quality; power system stability; MATLAB; active islanding detection technique; average absolute frequency deviation value; computer simulation; continuous periodic reference current; frequency relay; inverter classical q-axis current controller; nondetection zone; nonislanding switching events; power factor degradation; power quality degradation; Frequency control; Inverters; Islanding; Market research; Q-factor; Reactive power; Switches; Average absolute frequency deviation value (AFDV $_{rm avg}$ ); Average absolute frequency deviation value (AFDVavg); distributed generation (DG); islanding detection technique (IDT);
fLanguage :
English
Journal_Title :
Smart Grid, IEEE Transactions on
Publisher :
ieee
ISSN :
1949-3053
Type :
jour
DOI :
10.1109/TSG.2014.2337751