• DocumentCode
    1510054
  • Title

    Detection of air in helium filled thermal conduction modules

  • Author

    O´Hanlon, John F.

  • Author_Institution
    IBM Thomas J. Watson Res. Center, Yorktown Heights, NY, USA
  • Volume
    14
  • Issue
    1
  • fYear
    1991
  • fDate
    3/1/1991 12:00:00 AM
  • Firstpage
    211
  • Lastpage
    213
  • Abstract
    Two thermal conductance techniques for detecting air contamination in a helium-filled thermal conduction module (TCM) used to package silicon chips are described. A silicon majority carrier thermistor was used to detect as little as 15% air contamination in a container filled with helium. The technique directly measured the internal cooling ability of the package. Both a static test and a transient test were developed. The transient test is shown to be independent of the thermistor packaging. The technique did not require any modification to a TCM. Most importantly, the technique directly measured the cooling ability of the fill gas. The measurement could be performed simply and routinely after assembly, or on return from the field
  • Keywords
    cooling; helium; modules; packaging; production testing; thermal resistance measurement; He filled thermal conduction modules; Si chips packaging; Si majority carrier thermistor; TCM; air contamination detection; internal cooling ability; routine test method; static test; transient test; Containers; Contamination; Cooling; Helium; Packaging; Pollution measurement; Silicon; Testing; Thermal conductivity; Thermistors;
  • fLanguage
    English
  • Journal_Title
    Components, Hybrids, and Manufacturing Technology, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0148-6411
  • Type

    jour

  • DOI
    10.1109/33.76534
  • Filename
    76534