DocumentCode :
1510617
Title :
Influence of Angle of View on Temperature Measurements Using Thermovision Camera
Author :
Litwa, Mariusz
Author_Institution :
Div. of Metrol. & Optoelectron., Poznan Univ. of Technol., Poznan, Poland
Volume :
10
Issue :
10
fYear :
2010
Firstpage :
1552
Lastpage :
1554
Abstract :
The influence of the angle of view on the reliability of temperature measurements using thermovision cameras was studied. The experimental setup consisted of a camera and infrared radiator, which allows for temperature adjustment and changes in the angle of view. The experiments were conducted in the laboratory. Preselected distance intervals between the camera and radiator were observed. Three thermovision cameras were used in the measurements. The critical value for the angle of view was determined.
Keywords :
cameras; infrared detectors; temperature measurement; angle of view; infrared radiator; temperature measurement; thermovision camera; Angle of view; measurement error; thermovision;
fLanguage :
English
Journal_Title :
Sensors Journal, IEEE
Publisher :
ieee
ISSN :
1530-437X
Type :
jour
DOI :
10.1109/JSEN.2010.2045651
Filename :
5482017